Thermostats

Safe:

UL Listed, GFCI Class A, 5mA trip level, GFCI disconnects L and N (L2), Grounded Neutral Detection, Glass coated, waterproof floor sensor provides protection against overheating to preserve sensitive floor materials

User Friendly:

Easy to operate, Factory pre-programmed to meet standard household requirements, dual voltage (120V or 240V), Easy switching between °F and °C, Inclined display for ease of viewing

Easy to Install:

Simply fasten wires into screw terminals, fit it into the wall box and set the date and time

Efficient:

Models with built-in clock function offer comfort and setback temperature mode

Thermostat Installation PDF
 
Thermostat User Manual PDF

PROGRAMABLE THERMOSTATS


Digital

Programable

Built in GFCI

Senses Floor Temperature

Thermostats

The Microline thermostat is designed to control electric radiant heating systems for maximum comfort and minimum power consumption. The system temperature is controlled by an external or built-in sensor. The heat output is switched on or off with a difference of 0.7°F(0.4°C).

The Microline thermostat has a built-in clock function for automatic comfort and setback temperature options. To simplify start ups the thermostats are supplied with a factory set 4-event program which can be changed if desired:

DAY 1-5
event time temperature F100 f temp
1 6am-8am Comfort 25°C/77°F
2 8am-4pm Setback 20°C/68°F
3 4pm-10:30pm Comfort 27°C/81°F
4 10:30pm-6am Setback 20°C/68°F

 

DAY 6-7
event time temperature F100 f temp
1 8am-11pm Comfort 27°C/81°F
4 11pm-8am Setback 20°C/68°F

 

In addition, the Microline thermostat offesr an adaptive logic function. The thermostat calculates when the heating system has to be switched on to ensure that the desired ‘comfort’ temperature level is obtained as scheduled.

Ground Fault Circuit Interrupter
The thermostats are equipped with a GFCI, Class A, 5mA trip level. In case of a ground fault the GFCI feature disconnects both lines to the heating element. This dual mode thermostat is suitable for 120/240V, 50/60 Hz power supply.

Individual Programming Of Events:
The factory pre-set programming can be changed and the following programs can be selected:

        4 events 6 days and 2 events day 7

        4 events per day

 

Monitoring Of Energy Consumption:
The percentage of total switch-on time can be read-out within 2, 30, or 365 day periods. This allows an easy monitoring of the heat consumption.

Backup Function:
In the event of a power failure, an internal circuit will maintain the programming and time settings. However, the time will have to be reset if the power failure exceeds 50 hours.

Comfort Mode:
The temperature can be temporarily changed for a single event. The comfort mode temperature is reset at the next event, and the thermostat will return to the scheduled program.

Manual Mode:
The scheduled event program can be cancelled, e.g., during holidays the temperature level can be adjusted to 41°F (5°C) for frost protection. The new setpoint is valid until the manual mode is cancelled.

 

Technical Data
Supply Load
120/240V AC+10/-15% 16A max Max. 1920W, 120V AC
50/60 Hz (resistive load) Max. 3840W, 240V AC

 

Temperature Range Ambient Temperature Range:
+5/+40°C Thermostat 0/40°C, +32/+104°F
+41/+104°F GFCI -35/+65°C, -31/+149°F

 

GFCI Dimensions (HxWxD) Size of Display
Class A 118x74x48mm 25x22mm
(5mA trip level) 4.65x2.90x1.90inch 1x0.85inch

 

 

 