PROGRAMABLE THERMOSTATS
Digital
Programable
Built in GFCI
Senses Floor Temperature
|
 |
The Microline thermostat is designed to control electric radiant heating systems for maximum comfort and minimum power consumption. The system temperature is controlled by an external or built-in sensor. The heat output is switched on or off with a difference of 0.7°F(0.4°C).
The Microline thermostat has a built-in clock function for automatic comfort and setback temperature options. To simplify start ups the thermostats are supplied with a factory set 4-event program which can be changed if desired:
DAY 1-5
| event |
time |
temperature |
F100 f temp |
| 1 |
6am-8am |
Comfort |
25°C/77°F |
| 2 |
8am-4pm |
Setback |
20°C/68°F |
| 3 |
4pm-10:30pm |
Comfort |
27°C/81°F |
| 4 |
10:30pm-6am |
Setback |
20°C/68°F |
DAY 6-7
| event |
time |
temperature |
F100 f temp |
| 1 |
8am-11pm |
Comfort |
27°C/81°F |
| 4 |
11pm-8am |
Setback |
20°C/68°F |
In addition, the Microline thermostat offesr an adaptive logic function. The thermostat calculates when the heating system has to be switched on to ensure that the desired ‘comfort’ temperature level is obtained as scheduled.
Ground Fault Circuit Interrupter The thermostats are equipped with a GFCI, Class A, 5mA trip level. In case of a ground fault the GFCI feature disconnects both lines to the heating element. This dual mode thermostat is suitable for 120/240V, 50/60 Hz power supply.
Individual Programming Of Events: The factory pre-set programming can be changed and the following programs can be selected:
4 events 6 days and 2 events day 7
4 events per day
Monitoring Of Energy Consumption: The percentage of total switch-on time can be read-out within 2, 30, or 365 day periods. This allows an easy monitoring of the heat consumption.
Backup Function: In the event of a power failure, an internal circuit will maintain the programming and time settings. However, the time will have to be reset if the power failure exceeds 50 hours.
Comfort Mode: The temperature can be temporarily changed for a single event. The comfort mode temperature is reset at the next event, and the thermostat will return to the scheduled program.
Manual Mode: The scheduled event program can be cancelled, e.g., during holidays the temperature level can be adjusted to 41°F (5°C) for frost protection. The new setpoint is valid until the manual mode is cancelled.
Technical Data
| Supply |
Load |
| 120/240V AC+10/-15% |
16A max |
Max. 1920W, 120V AC |
| 50/60 Hz |
(resistive load) |
Max. 3840W, 240V AC |
| Temperature Range |
Ambient Temperature Range: |
| +5/+40°C |
Thermostat |
0/40°C, +32/+104°F |
| +41/+104°F |
GFCI |
-35/+65°C, -31/+149°F |
| GFCI |
Dimensions (HxWxD) |
Size of Display |
| Class A |
118x74x48mm |
25x22mm |
| (5mA trip level) |
4.65x2.90x1.90inch |
1x0.85inch |
|